Kungani i-Diesel Generator ingathunyelwa isikhathi eside? Ukucatshangelwa okuyinhloko yile:
Uma isebenza ngaphansi kwama-50% wamandla alinganiselwe, ukusetshenziswa kwamafutha ka-Diesel Generator Setha kuzokwenyuka, injini yedizili kuzoba lula ukufaka ikhabhoni, ukukhulisa izinga lokuhluleka futhi linciphise umjikelezo we-averhaul.
Ngokuvamile, isikhathi sokusebenza sokulayishwa se-Diesel Generator ngeke sidlule imizuzu emi-5. Ngokuvamile, injini ifudunyezwa imizuzu emi-3, bese ijubane lenyuke liye kwijubane elilinganiselwe, futhi umthwalo ungathathwa lapho i-voltage iqinile. Isethi ye-generator izosebenza okungenani nomthwalo we-30% wokuqinisekisa ukuthi injini ifinyelela ekushiseni kokusebenza okudingekayo ekusebenzeni okujwayelekile, gwema ukushiswa kwamafutha, ukuqeda ukugqokwa kwamafutha, ukuqeda ukugqoka kwasekuqaleni kwe-cylinder liner futhi kwandise impilo yenkonzo ye injini.
Ngemuva kokuthi i-Diesel Generator iqalwe ngempumelelo, i-No-Load Voltage ingu-400V, imvamisa yi-50hz, futhi akukho ukuphambuka okukhulu ebhalansi ye-voltage yesigaba ezintathu. Ukuphambuka kwamandla kagesi kusuka ku-400V kukhulu kakhulu, futhi imvamisa iphansi kune-47hz noma ngaphezulu kuka-52hz. I-Diesel Generator izohlolwa futhi igcinwe ngaphambi kokuhlinzwa komthwalo; Okupholile kwi-radiator kufanele kugcwaliswe. Uma izinga lokushisa le-coolant lingaphezulu kwama-60 ℃, lingashintshwa ngomthwalo. Umthwalo wokusebenza kufanele ukhuphuke kancane emthwalweni omncane futhi usebenze njalo
Isikhathi sePosi: Aug-20-2021